TECAGLIDE green is an internally lubricated cast nylon that utilises a proprietary solid lubricant package. This state of the art technology allows the modified PA6 cast to show extremely good sliding and wear characteristics with very low friction and reduced abrasion, even in dry running conditions. The PA 6 C with lubricant is resistant to most petroleum based products, and exhibits a high level of ductility and toughness.

Facts

Chemical designation
PA 6 C (Cast polyamide 6)
Colour
green
Density
1.13 g/cm3

Main Features

  • good slide and wear properties
  • resistant to many oils, greases and fuels
  • electrically insulating
  • high toughness
  • good wear properties
  • high mechanical load capacity

Target industries

Technical details


  • product-technical-detail-collapse-item-0-lvl-1
    Mechanical properties Value Unit Parameter Norm
    Modulus of elasticity
    (tensile test)
    3200 MPa 1mm/min DIN EN ISO 527-2
    Tensile strength 76 MPa 50mm/min DIN EN ISO 527-2
    Tensile strength at yield 76 MPa 50mm/min DIN EN ISO 527-2
    Elongation at yield (tensile test) 14 % 50mm/min DIN EN ISO 527-2
    Elongation at break (tensile test) 18 % 50mm/min DIN EN ISO 527-2
    Flexural strength 103 MPa 2mm/min, 10 N DIN EN ISO 178
    Modulus of elasticity
    (flexural test)
    3100 MPa 2mm/min, 10 N DIN EN ISO 178
    Compression modulus 2500 MPa 5mm/min, 10 N EN ISO 604
    Compression strength 18/34/75 MPa 1% / 2% / 5% EN ISO 604
    Impact strength (Charpy) n.b. kJ/m2 max. 7,5J DIN EN ISO 179-1eU
    Notched impact strength (Charpy) 4 kJ/m2 max. 7,5J DIN EN ISO 179-1eA
    Shore hardness 79 D DIN EN ISO 868
  • product-technical-detail-collapse-item-1-lvl-1
    Thermal properties Value Unit Parameter Norm
    Glass transition temperature 45 C DIN EN ISO 11357
    Melting temperature 218 C DIN EN ISO 11357
    Thermal conductivity 0.38 W/(k*m) ISO 22007-4:2008
    Specific heat 1.7 J/(g*K) ISO 22007-4:2008
    Service temperature 130 C short term NN
    Service temperature 100 C long term NN
    Thermal expansion (CLTE) 11 10-5*1/K 23-60°C, long. DIN EN ISO 11359-1;2
    Thermal expansion (CLTE) 12 10-5*1/K 23-100°C, long. DIN EN ISO 11359-1;2
  • product-technical-detail-collapse-item-2-lvl-1
    Electrical properties Value Unit Parameter Norm
    surface resistivity 1014 DIN IEC 60093
    volume resistivity 1014 Ω*cm DIN IEC 60093
  • product-technical-detail-collapse-item-3-lvl-1
    Other properties Value Unit Parameter Norm
    Resistance to hot water/ bases (+) - -
    Flammability (UL94) HB - corresponding to DIN IEC 60695-11-10;
    Resistance to weathering - - -
    Water absorption 0.2 - 0.3 % 24h / 96h (23°C) DIN EN ISO 62
  • product-technical-detail-collapse-item-4-lvl-1
    Relative costs Value Unit Parameter Norm
    Relative costs EU from € to €€€€€€

Stock program